Ultrapure Water UV

Technical Series: NCL-T

Ultrapure Water

(TOC Reduction)

The Neotec UV NCL-T Series is a Vacuum Ultraviolet (VUV) system designed for TOC reduction in ultrapure water (UPW) treatment processes.

It utilizes high-output amalgam VUV lamps and CFD-based reactor optimization to achieve efficient organic compound oxidation, stable water quality, and reduced operating costs.

Available in standard and modular configurations, the system can be customized to accommodate various installation conditions and operational requirements.

Vacuum Ultraviolet Process

When exposed to Vacuum Ultraviolet (VUV) light at wavelengths below 200 nm, water molecules undergo photolysis, generating hydroxyl radicals (·OH). These highly reactive radicals break down organic compounds, reducing total organic carbon (TOC) levels.

VUV photolysis generates high concentrations of hydroxyl radicals (·OH) directly in water without the need for chemicals that could interfere with Ultrapure Water (UPW) treatment processes.
How VUV Works
1. VUV light irradiates water molecules.
2.  Photolysis generates hydroxyl radicals (·OH) without added chemicals.
3. Hydroxyl radicals oxidize organic compounds, reducing TOC levels.

Key Features

1) High-Efficiency Amalgam VUV Lamp Technology
The NCL-T Series features high-output amalgam lamps with a lifespan of up to 16,000 hours and power input of 300–330 W, requiring fewer lamps for efficient operation.
2) CFD-Based Reactor Optimization Design
CFD-based reactor optimization, such as lamp arrangement and baffle design, improves flow uniformity and enhances TOC removal efficiency in UPW processes.
3) Ozone Leakage Prevention & Lamp Protection
The specialized lamp socket provides enhanced sealing and vibration resistance to prevent ozone leakage while simplifying maintenance.
4) AI-based Lamp Output Control System (Option)
This system utilizes edge computing and machine learning to automatically optimize lamp output, maintaining stable water quality while reducing energy consumption.
‍

Applications

These industries require ultra-low TOC levels in process water and are sensitive to chemical contamination.
‍
• Semiconductor Manufacturing
• Display Manufacturing (LCD / OLED)
• Pharmaceutical Manufacturing
• Precision Electronics Manufacturing

System Design

The control panel features a user-friendly touchscreen, an intelligent electronic ballast for controlling up to four lamps with modular and linear output adjustment, and an optional AI-enabled edge computer.
‍
The UV reactor features customizable inlet/outlet connections, a VUV lamp, an electropolished STS316L stainless steel chamber, and sensors for real-time UV intensity and temperature monitoring.

Touchscreen Monitoring & Control

Lamp Control‍
Lamp operation and output can be adjusted according to site conditions, with manual and remote control options available.
Individual Lamp Output Control
Individual lamps can be independently controlled to meet target water quality requirements to reduce operating costs.
System Monitoring
Real-time monitoring of lamp, reactor, and ballast status supports stable operation and prompt response to system abnormalities.
Operating Range Settings
Temperature, UV intensity, and other operating parameters can be configured to maintain safe operating conditions.

Control Panel Configurations

NCL-T Series can be customized to meet specific site requirements, with options for a standard wall-mounted type or a modular control panel configuration.

Ultrapure UV Series

Specifications NCL-T350-E24 NCL-T300-E20 NCL-T250-E16 NCL-T350-E24 NCL-T350-E24
Chamber Material STS 316L
Chamber Length 2038 2042 2038 2010 2010
Chamber Height 572 600 550 500 450
Connection Size (mm/Inch) 100A 100A 100A 75A 75A
Connection Type Customized: ANSI, DIN, KS, JIS, Sanitary
Design Pressure 10 bar
Internal Surface Finish Machine Polish & Electro Polish (0.4Ra)
Sleeve Material Synthetic
Lamp
Lamp Number 24 20 16 8 4
Lamp Type Amalgam
Lamp Power Range 190W - 320W
Lamp Access Single Ended Access
Control Panel (Standard)
Width (mm) 283.5 283.5 283.5 283.5 283.5
Length (mm) 810 810 810 810 810
Height 1160 1160 958 758 758
Materials & Rating Carbon Steel / IP54
Color & Cooling Method Selectable / FAN (748 m3/h Filtered Air Flow)
Control Type Microprocessor
Ballast 300W Range Module ballst
Power Supply Voltage [220 - 240Vac, 3PH, 50/60Hz 3W +PG] [220-240Vac, 1PH, 50/60Hz, 2W + PG] [380Vac, 3PH, 50Hz, 4W + PG]
Serial Communication Modus TCP/IP
Digital Input/Output Dry Contact Input : 7ea , Output : 7ea
Analog Input/Output 4-20mA Input : 2ea, Output : 2ea
Control Panel (Modular)
Width (mm) 400 None None None None
Length (mm) 1750 None None None None
Height 540 None None None None
Materials & Rating Carbon Steel / IP54
Color & Cooling Method Selectable / FAN (748 m3/h Filtered Air Flow)
Control Type Microprocessor
Ballast 300W Range Module ballst
Power Supply Voltage [220-240Vac, 3PH, 50/60Hz 3W + PG] [220-240Vac, 1PH, 50/60Hz, 2W + PG] [380Vac, 3PH, 50Hz, 4W + PG]
Serial Communication Modus TCP/IP (Option)
Digital Input/Output Dry Contact Input : 7ea , Output : 7ea
Analog Input/Output 4-20mA Input : 2ea, Output : 2ea