UV AOP

Technical Series: NAOP

Pilot Plant Skid

(NAOP Series)

The Neotec UV Pilot Test Equipment is a compact, mobile system designed for flexible on-site testing and pre-verification of UV-AOP treatment processes.

It is used to simulate actual operating conditions to determine optimal UV and oxidant settings, and assess the degradation of refractory organic contaminants.

The test results provide essential data for optimizing full-scale treatment systems.

Key Features

The Neotec UV Pilot Test Equipment evaluates UV treatment performance to support full-scale system design and optimization.
‍
• Compact skid-mounted design, transportable by 1-ton truck
• Both Low-Pressure and Medium-Pressure UV chambers installed
• Batch testing through internal water circulation
• Adjustable flow rates and operating conditions
• Maximum flow rate of 100 m³/day for drinking water applications
• Spiking tests available for contaminant removal evaluation

Applications

• Drinking Water (Geosmin, 2-MIB, NDMA, 1,4 dioxane and etc.)
• Wastewater and Industrial Wastewater (TOC and COD Reduction, Organic Pollutants)

CBD Testing

When evaluating the applicability of UV AOP treatment conditions (e.g., LP/MP selection), CBD (Collimated Beam Device) testing is typically the first step, followed by pilot-scale testing to verify treatment performance.
‍
It uses a controlled UV beam to assess pollutant removal in industrial wastewater under various conditions.

Pilot Equipment Components

1. Flow Meter
Real-time measurement of Flow Rate.
2. MP UV Chamber
1.5-3kW MP Lamp Installed.
UV Intensity and Temperature sensor applied.
3. Water Supply Pump
Supply and control the flow of water using the Control System.
4. Control System
Monitoring and controlling lamp output.
UV intensity and flow rate.
5. LP UV Chamber
550W LP Lamp Installed.
UV Intensity sensor and Temperature sensor applied.
6. Oxidant Supply System
Supplying oxidants automatically from a storage tank.
Capable of supplying pollutants for a spiking test.

pilot equipment skid

Pilot Equipment General Specifications
Lamp Type Medium Pressure / Low Pressure
Size (mm) 1,500 (W) x 2,750 (L) x 1,655 (H)
Weight 1 ton
Chamber Material STS 316
Electrical Input 220V 3Phase
Operating Temperature LP 5-45°C, MP 5-65°C in Chamber
Sampling Parts 4 Installed (Inlet, Outlet for both LP / MP)
Size for Inlet, Outlet, Main Pipes 25A